<menuitem id="doicw"></menuitem>
  • <video id="doicw"><input id="doicw"><big id="doicw"></big></input></video>
      1. <address id="doicw"></address>
      <video id="doicw"><bdo id="doicw"></bdo></video><blockquote id="doicw"><track id="doicw"></track></blockquote>
    1. <pre id="doicw"><strong id="doicw"></strong></pre>

      < >

      Magnetic auxiliary contact pressure gauge

      YXC-100 and YXC-103 magnetic auxiliary contact pressure gauges (Shanghai automation instrument four factory) - Baiyun brand Magnetic auxiliary contact pressure gauges are widely used in measuring the pressure of all kinds of fluid media without explos
      Quality assurance: the company strictly implement the relevant national warranty regulations, product warranty for one year.
      After sales service: from the industry instrument to provide delivery, and provide after-sales service.
      Reference price:

      YXC-100 and YXC-103 magnetic auxiliary contact pressure gauges (Shanghai automation instrument four factory) - Baiyun brand

      Magnetic auxiliary contact pressure gauges are widely used in measuring the pressure of all kinds of fluid media without explosion at the petroleum, chemical, metallurgy, power plant and other mechanical and electrical equipment. Usually, the instrument is matched with the corresponding electrical devices (such as relays and contactors, etc.), and the automatic control and sending (alarm) of the measured pressure system can be realized.
      In order to adapt to the different needs of the object to be measured and the instrument based on the original series, common type and special type, they have developed a vibration resistant, corrosion resistant, corrosion resistant type anti vibration isolation device and with other types of more than 10 types of products.
      In view of this series of instrument not only has the characteristics of novel structure, reliable equipment, complete specifications, good stability and strong adaptability, but also has the advantages of simple installation, measurement and control, and, less maintenance. Therefore, it is generally no indication, no switch adjustment and no set pressure controller of the device There is nothing comparable to this. Pressure measuring instrument.
       
      Model designation
       
      Main technical indexes and functions

      ◆Scale range, accuracy grade and joint thread size

      type
      Model
      Name (including whole or short)
      標度范圍
      MPa
      Accuracy class
      Joint thread size
      Instructions
      Setting value
      接通
      斷開
      Ordinary type
      YXC-100
      Magnetic auxiliary contact pressure gauge
      0~0.6至60及-0.1~0.06至2.4系列 
      1.6
      1.6
      4
      M20×1.5
      (*G3/8″)
      (*G1/2″) 
      *YXC-102
      YXC-103
      YXC-150
      0~0.1至60及-0.1~0至2.4系列
      *YXC-153
       Special type
      YXCA-150
      Magnetic auxiliary contact ammonia pressure gauge
      0~0.16至60及-0.1~0.06至2.4系列 
      2.5
      2.5
      4
      Vibration resistant type
      YXC-100-Z
      Magnetic auxiliary contact pressure gauge
      0~0.6至60及-0.1~0.5至2.4系列
      1.6
      1.6
      5
       *YXC-102-Z
       YXC-103-Z 
      Corrosion-resistant type
      *YXC-100B-F
      0~0.16至60及-0.1~0.06至2.4系列
      1.6
      1.6
      4
      *YXC-102B-F 
      *YXC-103B-F
      *YXC-150B-F
      *YXC-152B-F 
      Corrosion resistant and vibration resistant type
      *YXC-100B-FZ
      0~0.6至60及-0.1~0.5至2.4系列
      1.6
      1.6
      5
      *YXC-102B-FZ
      *YXC-152B-FZ
      *YXC-153B-FZ
      Isolated type
      YXCG-103
      Isolated magnetic contact pressure gauge
      0~0. 16至60及-0.1~0.06至2.4系列
      1.6
      1.6
      4
      M42×2
      (*G1?″)
      Isolated corrosion-resistant type
      *YXCG-103-F
      Isolated anti vibration type
      YXCG-103-Z
      0~0. 6至60及-0.1~0.5至2.4系列
      1.6
      1.6
      5
      Isolated type
      Corrosion resistant and vibration resistant type
       
      *YXCG-103-FZ

      Note: 1. models marked "*" are limited to special orders
      2. isolated soft tail lengths of 1, 2, 3 and 4m (of which 2m is preferred length)

      ◆Electrical parameters and control forms of contact devices
      Contact power
      Maximum operating voltage
      Maximum operating current
      Control form
      30VA(阻性負載)
      220V DC或380V AC
      1A
      Upper and lower bounds, double upper bound, double lower bound
      Note: when the current is 1A, the operating voltage should be below 40V


      ◆使用環境條件

      type
      Operating temperature range
      relative humidity
      Anti vibration performance
      medium
      surrounding environment
      Ordinary type, special type
      -40-70℃
      不大于85%
      V.H.3級
      Corrosion-resistant type
      -25-55℃
      不大于90%
      V.H.3級
      Vibration resistant, corrosion resistant and vibration resistant
      V.H.4級
      Isolated type
      150℃以下
      -40-70℃
      V.H.3級
      Isolated corrosion-resistant type
      -40-70℃
      Isolated, other type
      150℃以下
      -25-55℃
      V.H.4級
      Temperature influence: indicating value is not more than 0.4%/10 Celsius, setting point is not more than 0.6%/10 degrees Celsius (using temperature deviation 20 + 5 degrees Celsius)
       
      Structure principle
      The instrument comprises a measuring system, an indicating device, a magnetic auxiliary electric contact device, a shell, an adjusting device and a junction box (a plug seat).
      The working principle of the instrument is the spring pipe in the measuring system under the action of the pressure of the measured medium based on the force generated by the end of spring pipe corresponding elastic deformation displacement, the transmission rod through a gear drive mechanism with and zoom, indicating pointer is fixed on the axle of the gear (along with contact) by the measured value indicated in the table. At the same time, when the contact and set on the pointer (upper or lower) contact (break or close) instantaneous, resulting in the circuit control system can be switched on or off in order to achieve the purpose of automatic control and alarm.
       
      Schematic diagram of electrical wiring connection
       
      Shape and size unit: mm

       


      Guide to selection quotation:

      The customer needs to provide the dial diameter, measuring range, interface thread size and material of the magnetic assistance contact pressure gauge.
      For example: select dial 150mm, range: 0~2.5MPa, M20 * 1.5 interface thread, ordinary material, then type is: YXC-150.


      Recommend

      Online Message

      • Theme:
      • Name:
      • Tel:
      • QQ:
      • Email:
      • Message:
      极品少妇XXXX
      <menuitem id="doicw"></menuitem>
    2. <video id="doicw"><input id="doicw"><big id="doicw"></big></input></video>
        1. <address id="doicw"></address>
        <video id="doicw"><bdo id="doicw"></bdo></video><blockquote id="doicw"><track id="doicw"></track></blockquote>
      1. <pre id="doicw"><strong id="doicw"></strong></pre>